IPDP - installation and operating instructions
25
3.2.3 Time Parameters
After making changes use the save changes button.
1 – max. time, for which the DoorPhone is hanging up, this time can be
extended during call by sign choice from telephone (* or #) – see page 22.
2 – Number of incoming call rings, the DoorPhone pick up after preseted
number of rings. After detection first ring – LED on front panel blinking. The
number can be set from 1 to 9.
3 – max. time [sec] among button presses [range 1-9]
- switch closing – if time between two next presses is bigger than w
time, the code is not evaluated correctly.
- dialing – if the button, we are pressing, is the first password number
for switch closing, so the choice is delayed by this w time.
4 – time [sec] for which the guard will hang up, before repeated dialing (button
pressing during call or dialing, busy tone detection) [range 1-5]
5 – after finishing the dialing it calculates time (ringing tones). If the number
exceeds time in second, it will hang up [range 10-99]. The dialing is
repeated in case, when the dialing mode of 2 groups is set.
6 – In default is status of DoorPhone signalling acoustically. If signalling makes
problem, so this signalling pick up / hang up prohibited.
7 – In default is status of DoorPhone signalling acoustically. If signalling makes
problem, so this signalling others tones prohibited.
8 – Default value – presetings to the firm settings. After making changes use
the save changes button.